Lighting control obligations, explained.
Clear answers on the German GModG and the EU Energy Performance of Buildings Directive. Every page starts with the short answer, cites its source and carries a review date.
Basics
Lighting control glossary: 45 terms from 0-10 V to zoning
Lighting control glossary: occupancy sensors, DALI, LLLC, hold time, GModG, EPBD, LENI, DIN/TS 18599 and more technical terms, each explained in one sentence.
Read →GModG timeline: what applies when for non-residential buildings
GModG timeline: in force since 29.07.2026, further stages in 2027, 2028 and 2030. All German deadlines 2026–2033 for non-residential buildings and lighting.
Read →Law & obligations
GModG exemption: when is lighting control unreasonable?
When does the German lighting control duty under Section 56 GModG not apply? Technical impossibility, economic unreasonableness, a worked example and documents.
Read →The 70 kW threshold in Germany: is your building affected?
When does the 70 kW threshold in Section 56 GModG apply? What counts per system, when outputs are added, who is responsible, plus a quick check with examples.
Read →EnEfG and EED: energy audits, implementation plans and lighting
German EnEfG and EU EED duties: energy management above 7.5 GWh, implementation plans above 2.5 GWh, status of bill 21/8027 and where lighting control fits.
Read →Energy certificates for non-residential buildings from 2027
German energy certificates for non-residential buildings from 1 Jan 2027: demand-based certificate for sale and letting, classes A–G and why lighting counts.
Read →Building automation under GModG Section 56: duty and functions
Building automation under Section 56(1) GModG: German duty above 70 kW by 31.12.2029, the six functions, new builds, transition, fines and inspections.
Read →GEG Section 71a vs. GModG Section 56: building automation changes
GEG Section 71a vs. GModG Section 56: threshold 290 to 70 kW, deadline 2024 to 2029, new functions, lighting control, fines and existing systems.
Read →GModG Section 56 full text: German original and translation
GModG Section 56 full text: all six subsections on building automation and lighting control in the German original, with an unofficial English translation.
Read →Lighting control obligation: Section 56(6) GModG explained
Section 56(6) GModG requires automatic lighting control in German non-residential buildings above 70 kW by 31 Dec 2029. Duties, exemptions and fines.
Read →Minimum energy performance for non-residential buildings 2030
Minimum energy performance for existing non-residential buildings in Germany (Section 40 GModG): 3.5 × reference from 2030, 2.95 × from 2033, exemptions.
Read →Technology & planning
DALI, KNX or wireless lighting control: which one fits?
DALI, KNX, wireless or 0-10 V compared: cabling, cost drivers, BACnet integration, vendor lock-in and scalability, with a decision guide for existing buildings.
Read →Fluorescent tube ban in the EU: what building owners should plan
EU fluorescent tube ban under RoHS: deadlines for T5, T8 and compact lamps, what is still allowed, and why the LED switch is the time to add sensors.
Read →Retrofitting lighting control to existing LED luminaires
Retrofitting lighting control without new luminaires: driver requirements, reading the type plate, AUX or EFS104, wireless instead of cabling, process.
Read →High-bay occupancy sensors for warehouses: 6 to 15 m explained
High-bay occupancy sensors for warehouses: sensor and lens by mounting height, racking aisles, forklift lead, hold times, IP66 and common mistakes.
Read →Presence detector vs motion sensor: differences and use cases
Presence detector or motion sensor? Differences, PIR, ultrasonic, microwave and dual-tech, use in offices, halls, corridors and toilets, and Section 56 GModG.
Read →Daylight harvesting control: function, zones and real savings
Daylight harvesting explained: light sensor, constant light, daylight zones, calibration, LBNL savings, common mistakes and Germany's 2027 reference building.
Read →Zoning and occupancy detection under § 56 GModG explained
What appropriate zoning and occupancy detection under Germany's § 56 GModG mean in practice: zones by building type, sensors, mounting heights and mistakes.
Read →Savings & verification
Lighting control savings: how to calculate and verify them
How to calculate and verify lighting control savings: reference consumption, multiplying factors, LBNL values, a worked example and before/after measurement.
Read →Lighting control costs: what drives them and when they pay back
Lighting control costs explained: what drives the cost of occupancy sensors, DALI and wireless, how to calculate payback and what a reliable quote needs.
Read →Funding
EU taxonomy and lighting control: activities 7.3, 7.5 and 7.7
EU taxonomy and lighting control: occupancy and daylight control in 7.5, LED in 7.3, monitoring above 290 kW in 7.7, CSRD after the Omnibus and evidence needed.
Read →Funding for lighting control in Germany 2026: BEG EM and EEW
German funding for lighting control in 2026: lighting dropped as a BEG EM measure, building automation class B at 15 %, EEW modules, applying in advance.
Read →Standards & energy balance
Europe
EPBD Article 13: lighting control in Germany and the EU
EPBD Article 13(12) requires lighting control in two stages; Germany applies one deadline, 2029, above 70 kW. Germany and EU compared, plus seven countries.
Read →Lighting control in Austria and Switzerland: status 2026
Lighting control duties in Austria and Switzerland: Vienna, Lower Austria and Tyrol above 290 and 70 kW, Upper Austria draft, MuKEn 2025 and SIA 387/4.
Read →From your question to a finished plan.
Free initial consultation, one contact person.