- Applies from
- 1 Jan 2027 (Art. 2 with Art. 9(2), BGBl. 2026 I No. 226)
- Sale and letting
- demand-based certificate under Section 81 (Section 80(3) sentence 2 GModG)
- Efficiency classes
- A to G by ratio to the reference building (Section 86(3)–(4), Annex 10a GModG)
- Class A
- zero-emission buildings only (Section 86(3) sentence 2 GModG)
- Format
- digital and machine-readable, paper on request (Section 79(2) GModG)
- Display
- where there is heavy public footfall (Section 80(6)–(7) GModG)
What changes on 1 January 2027?
The GModG (German Building Modernisation Act, Gebäudemodernisierungsgesetz) has been in force since 29 July 2026 and replaced the former Building Energy Act (GEG). Its parts take effect in stages. The new rules on energy certificates (Sections 79 to 87 and the new Annex 10a) are in Article 2 of that act and apply from 1 January 2027 under Article 9(2). All key dates are listed in the GModG timeline.
When is a demand-based certificate mandatory?
Section 80(3) sentence 1 lists the triggers: sale, creation or transfer of a heritable building right, letting, leasing and the extension of such contracts. For non-residential buildings, sentence 2 sets the type of certificate:
In the cases of sentence 1, an energy certificate based on an energy balance calculation under Section 81 shall be issued for a non-residential building.
Section 80(3) GModG (unofficial translation)
A new certificate is only needed where no valid certificate exists. An existing consumption-based certificate therefore remains usable for the rest of its validity. That is a deferral rather than an escape: from 2027, Section 82 covers consumption-based certificates only for buildings used exclusively for residential purposes. On our reading, no new consumption-based certificates will be issued for non-residential buildings. Sellers, landlords and agents must present the certificate at the latest at the viewing and hand it over after the contract is signed (Section 80(4)–(5)). Breaches can be fined under Section 108.
How do the new classes A to G work?
The decisive figure is the ratio: the building's calculated primary energy demand divided by the primary energy demand of the reference building. A ratio of 1.0 means the building performs exactly like the reference. Under Section 86(4) sentence 2, a primary energy factor of 0.7 is always used for the reference building.
| Class | Ratio (Annex 10a GModG) |
|---|---|
| A | ≤ 1.0 (zero-emission buildings only) |
| B | > 1.0 |
| C | > 1.48 |
| D | > 1.97 |
| E | > 2.46 |
| F | > 2.95 |
| G | > 3.5 |
Only non-residential buildings that cause no emissions from the use of fossil energy at the building site (zero-emission buildings) may be placed in efficiency class A.
Section 86(3) GModG (unofficial translation)
The F and G limits are more than information. From 2030 and 2033, the minimum energy performance rule in Section 40 is tied to exactly these values.
What must the certificate state?
Section 85(1) lists 31 minimum items. For non-residential buildings, the most relevant are:
- efficiency class and ratio to the reference building (Nos. 9 and 28)
- calculated primary, final and useful energy (Nos. 10, 11, 23 and 25)
- operational greenhouse gas emissions per m² and year (No. 16)
- whether systems subject to inspection under Section 74(1) are present (No. 21)
- whether the building can respond to external signals (No. 26)
Renovation recommendations under Section 84 must include an estimate of energy savings and emission reductions. The certificate must be issued digitally in a machine-readable format, and on paper on request (Section 79(2)).
Who has to display the certificate?
Publicly owned non-residential buildings used by an authority need a demand-based certificate, which must be displayed prominently where there is heavy public footfall (Section 80(6)). Where an authority uses a privately owned building, the duty to display lies with the user. Owners of other non-residential buildings with heavy public footfall must display a certificate as soon as and for as long as one exists (Section 80(7)). The new wording sets no floor-area threshold. An extract based on the official template, without recommendations, is sufficient (Section 80(6) and (8)).
Why does lighting count in the certificate?
For non-residential buildings, the balance covers annual primary energy demand for heating, hot water, ventilation, cooling and built-in lighting (Section 18(1) for new buildings and Section 38(1) for altered buildings, to which Section 81(2) refers for existing-building certificates). From 2027 the calculation follows DIN/TS 18599:2025-10, with lighting in part 4 and building automation in part 11.
The reference building in Annex 2 has also become more demanding: LEDs in LED luminaires, presence detectors and daylight-dependent control in specified zones, and building automation class C. A building with fluorescent tubes and manual switching is therefore measured against a considerably better reference. Details are in the article on the reference building lighting from 2027.
LED lowers installed load. Presence and daylight-dependent control lower calculated operating hours and light levels. Both reduce primary energy demand while the reference stays the same, so the ratio falls.
Illustrative example
All values are example assumptions for illustration only, not official or typical values.
| Item | Example assumption |
|---|---|
| Ratio before | 3.1 (class F) |
| Lighting share of primary energy demand | 30 % |
| Lighting reduction from LED and controls | 60 % |
| Overall reduction | 30 % × 60 % = 18 % |
| Ratio after | 3.1 × 0.82 ≈ 2.54 (class E) |
In buildings with high heating demand, lighting has a smaller share, and the calculation also accounts for interactions such as lower heat output from luminaires. Even there, every step below the 3.5 and 2.95 limits counts, and lighting can be converted during operation without touching the envelope or heating. For buildings above 70 kW, Section 56(6) requires automatic lighting control by 31 December 2029 in any case.
What should owners do now?
- Check your certificates: which type you hold, when it expires, and whether a sale or new letting is planned.
- Gather data: installed lighting load, luminaire types, existing controls, zones and operating hours. If the owner supplies data, the owner is responsible for its accuracy under Section 83(3).
- Have the class estimated early: an energy consultant can show where the building stands and which measure lowers the ratio most.
- Plan lighting first: if you replace luminaires or add sensors, do so before the new certificate is issued. SensMotion documents zones, sensors and consumption in its monitoring, which makes data collection easier for the certificate issuer.
Frequently asked questions
Does my old consumption-based certificate remain valid after 2027?
Yes, for as long as it is valid. Section 80(3) only requires a new certificate where no valid one exists. Once it expires, a demand-based certificate is needed to sell or let a non-residential building.
Will every non-residential building get a class from A to G?
Every certificate for a non-residential building issued from 2027 must state the class under Section 86(3) and Annex 10a. Older certificates do not show the new class.
Why can my building not reach class A even though its ratio is below 1.0?
Class A is reserved for zero-emission buildings, meaning buildings with no emissions from fossil energy at the site. A gas condensing boiler in the building therefore rules out class A.
How much does lighting influence the class?
That depends on lighting's share of total primary energy demand, which is often noticeable in offices, retail and halls with long operating hours. Only the calculation for your building gives a reliable answer.
Last reviewed: 18 November 2026. General information, not legal advice. The legal text is authoritative.