Offices & rooms
EFS107E
12 V Dual-Tech Ceiling Sensor (PIR + Ultrasonic). Dual-tech with PIR and ultrasonic: also detects quiet desk work and meeting rooms.
- 12 V DC input
- Powered via luminaire controllers (PPA104S.B1, PPA104S-D.B1, PPA102S.F1)
- Covers rooms up to 56 m²
- Daylight harvesting
- Dual-tech PIR + ultrasonic for high accuracy
- AlgoH™ algorithm against false triggers
Technical data
| Input voltage | 12 V DC |
|---|---|
| Wireless | No radio module of its own (eco sensor, connected via controller) |
| Sensing | PIR + ultrasonic + daylight |
| Coverage area | Up to 56 m² |
| Temperature range | −30 °C to 55 °C |
| Ingress protection | IP20 |
| Housing | Flame-retardant plastic (class V-0), white |
| Standards | CE, RoHS (EU Directive 2011/65/EU) |
| Compatible controllers | PPA104S.B1, PPA104S-D.B1, PPA102S.F1 |
| Connection | PH2.0; RTP converter to RJ45 eco port |
| Coverage (diagram) | 10 × 5 m at approx. 3 m mounting height (PIR + ultrasonic) |
| Dimensions | Ø 115 mm |
Where we use it
In single and open-plan offices and meeting rooms where people sit still for long periods. The ultrasonic sensing stops the light from going off.
Typical applications: Private and open-plan offices, Hallways and corridors, Classrooms, Meeting rooms, Healthcare / patient rooms
Manufacturer data. Which components make sense in your building is decided in the 3D planning. Occupancy detection, zoning and monitoring are included with every sensor.
Getting started
From your question to a finished plan.
Free initial consultation, one contact person.
Send a photo of the driver labelWe check free of charge whether your luminaires can be retrofitted.
Add your floor planWe turn it into a 3D model with sensors and zones.
Planning and quoteYou see the result in 3D first, then you decide.